SCHNEIDER
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NC aux. - 24 V DC coil - LP1K0901BD3
LP1K0901BD3
€28.96 Excl. Tax
€34.75 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | TeSys K |
---|---|
Range: | TeSys |
Product or component type: | Contactor |
Device short name: | LP1K |
Contactor application: | Motor controlResistive load |
Utilisation category: | AC-3AC-1AC-4 |
Poles description: | 3P |
Pole contact composition: | 3 NO |
[Ie] rated operational current: | 20 A (at 9 A at 16 A (at |
Auxiliary contact composition: | 1 NC |
Coil technology: | Built-in bidirectional peak limiting diode suppressor |
---|---|
Auxiliary contacts type: | type instantaneous 1 NC |
Control circuit voltage limits: | Operational: 0.8...1.15 Uc (at Drop-out: 0.1...0.75 Uc (at |
[Ui] rated insulation voltage: | Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
[Uimp] rated impulse withstand voltage: | 8 kV |
Overvoltage category: | III |
Mounting support: | RailPlate |
Flame retardance: | V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102 |
Tightening torque: | 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 21.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm |
[Ue] rated operational voltage: | Power circuit: 690 V AC 50/60 HzSignalling circuit: |
[Ith] conventional free air thermal current: | 20 A (at 50 °C) for power circuit10 A (at 50 °C) for signalling circuit |
Irms rated making capacity: | 110 A AC for power circuit conforming to NF C 63-110110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947 |
Rated breaking capacity: | 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
Associated fuse rating: | 25 A gG at 25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660 |
Average impedance: | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Inrush power in W: | 3 W (at 20 °C) |
Hold-in power consumption in W: | 3 W at 20 °C |
Operating time: | 30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening |
Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Mechanical durability: | 10 Mcycles |
Maximum operating rate: | 3600 cyc/h |
Minimum switching current: | 5 mA for signalling circuit |
Minimum switching voltage: | 17 V for signalling circuit |
Insulation resistance: | > 10 MOhm for signalling circuit |
Height: | 58 mm |
Width: | 45 mm |
Depth: | 57 mm |
Product weight: | 0.225 kg |
Compatibility code: | LP1K |
In short
Reference LP1K0901BD3
Product Name TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NC aux. - 24 V DC coil - LP1K0901BD3
Range TeSys
Device function Contrôle
Related Categories