Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NC aux. - 220 V DC coil - LP1K12015MD

LP1K12015MD

€23.93 Excl. Tax
€28.72 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range of product: TeSys K
Range: TeSys
Product or component type: Contactor
Device short name: LP1K
Contactor application: Resistive loadMotor control
Utilisation category: AC-3AC-1AC-4
Poles description: 3P
Pole contact composition: 3 NO
[Ie] rated operational current: 20 A (at 12 A at 16 A (at
Auxiliary contact composition: 1 NC
Auxiliary contacts type: type instantaneous 1 NC
Control circuit voltage limits: Operational: 0.8...1.15 Uc (at Drop-out: 0.1...0.75 Uc (at
[Ui] rated insulation voltage: Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
Mounting support: Printed circuit boards
Flame retardance: V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102
[Ue] rated operational voltage: Power circuit: 690 V AC 50/60 HzSignalling circuit:
[Ith] conventional free air thermal current: 20 A (at 50 °C) for power circuit10 A (at 50 °C) for signalling circuit
Irms rated making capacity: 110 A AC for signalling circuit conforming to IEC 60947144 A AC for power circuit conforming to NF C 63-110144 A AC for power circuit conforming to IEC 60947
Rated breaking capacity: 110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
Associated fuse rating: 25 A gG at 25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660
Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit
Inrush power in W: 3 W (at 20 °C)
Hold-in power consumption in W: 3 W at 20 °C
Operating time: 30...40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 10 Mcycles
Maximum operating rate: 3600 cyc/h
Minimum switching current: 5 mA for signalling circuit
Minimum switching voltage: 17 V for signalling circuit
Insulation resistance: > 10 MOhm for signalling circuit
Height: 58 mm
Width: 45 mm
Depth: 57 mm
Product weight: 0.225 kg
Compatibility code: LP1K
In short
Reference LP1K12015MD
Product Name TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NC aux. - 220 V DC coil - LP1K12015MD
Range TeSys
Device function Contrôle
Related Categories