TeSys LP4K - contacteur - 3P - AC-3 440V - 9A - bobine 24Vcc - LP4K09013BW3
LP4K09013BW3
€33.96 Excl. Tax
€40.75 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | TeSys K |
---|---|
Range: | TeSys |
Product or component type: | Contactor |
Product name: | TeSys K |
Device short name: | LP4K |
Device application: | Control |
Contactor application: | Motor controlResistive load |
Utilisation category: | AC-1AC-3AC-4 |
---|---|
Poles description: | 3P |
Pole contact composition: | 3 NO |
[Ue] rated operational voltage: | 690 V AC 50/60 Hz for power circuit |
[Ie] rated operational current: | 9 A at 20 A (16 A ( |
Control circuit type: | DC low consumption |
[Uc] control circuit voltage: | 24 V DC |
Motor power kW: | 2.2 kW at 400 V AC 50/60 Hz AC-42.2 kW at 220...230 V AC 50/60 Hz AC-34 kW at 380...415 V AC 50/60 Hz AC-34 kW at 440 V AC 50/60 Hz AC-34 kW at 480 V AC 50/60 Hz AC-34 kW at 500...600 V AC 50/60 Hz AC-34 kW at 660...690 V AC 50/60 Hz AC-3 |
Auxiliary contact composition: | 1 NC |
[Uimp] rated impulse withstand voltage: | 8 kV |
Overvoltage category: | III |
[Ith] conventional free air thermal current: | 20 A at 10 A at |
Irms rated making capacity: | 110 A AC for power circuit conforming to NF C 63-110110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947 |
Rated breaking capacity: | 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
[Icw] rated short-time withstand current: | 20 A = 15 min power circuit90 A 85 A 80 A 60 A 45 A 40 A 80 A 1 s signalling circuit90 A 500 ms signalling circuit110 A 100 ms signalling circuit |
Associated fuse rating: | 25 A gG at 25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660 |
Average impedance: | 3 mOhm at 50 Hz - Ith 20 A for power circuit |
[Ui] rated insulation voltage: | 690 V for signalling circuit conforming to IEC 60947-4-1690 V for signalling circuit conforming to IEC 60947-5-1600 V for signalling circuit conforming to UL 508600 V for power circuit conforming to CSA C22.2 No 14600 V for signalling circuit conforming to CSA C22.2 No 14690 V for power circuit conforming to IEC 60947-4-1600 V for power circuit conforming to UL 508 |
Insulation resistance: | > 10 MOhm for signalling circuit |
Inrush power in W: | 1.8 W at 20 °C |
Hold-in power consumption in W: | 1.8 W at 20 °C |
Heat dissipation: | 1.8 W |
Control circuit voltage limits: | 0.7...1.30 Uc at 0.1...0.7 Uc at |
Connections - terminals: | Spring terminals 1 cable(s) 0.75...1.5 mm² - cable stiffness: solidSpring terminals 1 cable(s) 0.75...1.5 mm² - cable stiffness: flexible - without cable end |
Operating rate: | 3600 cyc/h |
Coil technology: | Built-in bidirectional peak limiting diode suppressor |
Auxiliary contacts type: | Type instantaneous (1 NC) |
Minimum switching current: | 5 mA for signalling circuit |
Minimum switching voltage: | 17 V for signalling circuit |
Mounting support: | PlateRail |
Operating time: | 10...20 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing |
Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Non overlap distance: | 0.5 mm |
Mechanical durability: | 30 Mcycles |
Electrical durability: | 0.18 Mcycles 20 A AC-1 at Ue 1.3 Mcycles 9 A AC-3 at Ue |
Mechanical robustness: | Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6Shocks contactor opened, on X axis 10 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Y axis 6 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on X axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Y axis 10 Gn for 11 ms IEC 60068-2-27 |
Height: | 58 mm |
Width: | 45 mm |
Depth: | 57 mm |
Product weight: | 0.235 kg |
In short