Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

TeSys LP4K - contacteur - 3P - AC-3 440V - 9A - bobine 24Vcc  - LP4K09013BW3

LP4K09013BW3

€33.96 Excl. Tax
€40.75 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range of product: TeSys K
Range: TeSys
Product or component type: Contactor
Product name: TeSys K
Device short name: LP4K
Device application: Control
Contactor application: Motor controlResistive load
Utilisation category: AC-1AC-3AC-4
Poles description: 3P
Pole contact composition: 3 NO
[Ue] rated operational voltage: 690 V AC 50/60 Hz for power circuit
[Ie] rated operational current: 9 A at 20 A (16 A (
Control circuit type: DC low consumption
[Uc] control circuit voltage: 24 V DC
Motor power kW: 2.2 kW at 400 V AC 50/60 Hz AC-42.2 kW at 220...230 V AC 50/60 Hz AC-34 kW at 380...415 V AC 50/60 Hz AC-34 kW at 440 V AC 50/60 Hz AC-34 kW at 480 V AC 50/60 Hz AC-34 kW at 500...600 V AC 50/60 Hz AC-34 kW at 660...690 V AC 50/60 Hz AC-3
Auxiliary contact composition: 1 NC
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 20 A at 10 A at
Irms rated making capacity: 110 A AC for power circuit conforming to NF C 63-110110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity: 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current: 20 A = 15 min power circuit90 A 85 A 80 A 60 A 45 A 40 A 80 A 1 s signalling circuit90 A 500 ms signalling circuit110 A 100 ms signalling circuit
Associated fuse rating: 25 A gG at 25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660
Average impedance: 3 mOhm at 50 Hz - Ith 20 A for power circuit
[Ui] rated insulation voltage: 690 V for signalling circuit conforming to IEC 60947-4-1690 V for signalling circuit conforming to IEC 60947-5-1600 V for signalling circuit conforming to UL 508600 V for power circuit conforming to CSA C22.2 No 14600 V for signalling circuit conforming to CSA C22.2 No 14690 V for power circuit conforming to IEC 60947-4-1600 V for power circuit conforming to UL 508
Insulation resistance: > 10 MOhm for signalling circuit
Inrush power in W: 1.8 W at 20 °C
Hold-in power consumption in W: 1.8 W at 20 °C
Heat dissipation: 1.8 W
Control circuit voltage limits: 0.7...1.30 Uc at 0.1...0.7 Uc at
Connections - terminals: Spring terminals 1 cable(s) 0.75...1.5 mm² - cable stiffness: solidSpring terminals 1 cable(s) 0.75...1.5 mm² - cable stiffness: flexible - without cable end
Operating rate: 3600 cyc/h
Coil technology: Built-in bidirectional peak limiting diode suppressor
Auxiliary contacts type: Type instantaneous (1 NC)
Minimum switching current: 5 mA for signalling circuit
Minimum switching voltage: 17 V for signalling circuit
Mounting support: PlateRail
Operating time: 10...20 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance: 0.5 mm
Mechanical durability: 30 Mcycles
Electrical durability: 0.18 Mcycles 20 A AC-1 at Ue 1.3 Mcycles 9 A AC-3 at Ue
Mechanical robustness: Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6Shocks contactor opened, on X axis 10 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Y axis 6 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on X axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Y axis 10 Gn for 11 ms IEC 60068-2-27
Height: 58 mm
Width: 45 mm
Depth: 57 mm
Product weight: 0.235 kg
In short
Reference LP4K09013BW3
Product Name TeSys LP4K - contacteur - 3P - AC-3 440V - 9A - bobine 24Vcc  - LP4K09013BW3
Range TeSys
Device function Contrôle
Related Categories