Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

Electronic thermal overload relay, TeSys Giga, 125…500 A, class 5E…30E, push-in control connection - LR9G500

LR9G500

€719.94 Excl. Tax
€863.93 Inc. Tax
available In stock – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range: TeSys
Product name: TeSys LRG
Product or component type: Electronic thermal overload relay
Device short name: LR9G
Relay application: Motor protection
Network type: AC
Thermal overload class: Class 5E...30E conforming to IEC 60947-4-1
Thermal protection adjustment range: 125...500 A
Network frequency: 30...60 Hz100 Hz
Overvoltage category: III
Tripping threshold: 1.125 +/- 0.07 In conforming to IEC 60947-4-1
Protection type: Ground fault protection - tripping time adjustment: 0...1 s - for alarm circuit conforming to IEC 60947-4-1Ground fault protection - tripping time adjustment: 0...1 s - for alarm circuit conforming to UL 60947-4-1Phase loss - tripping time adjustment: 0...4 s - for alarm circuitPhase imbalance - tripping time adjustment: 0...5 s - for alarm circuit conforming to IEC 60947-4-1Phase imbalance - tripping time adjustment: 0...5 s - for alarm circuit conforming to UL 60947-4-1
Local signalling: LEDTrip indicator
Contacts type and composition: 1 NO + 1 NC
[Ith] conventional free air thermal current: 5 A
[Uc] control circuit voltage: 24...500 V AC 50/60 Hz24...250 V DC
[Ue] rated operational voltage: 1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage: 8 kV
Reset: Automatic resetManual
Mechanical durability: 7000 cycles
Surge withstand: 4 kV
Electromagnetic compatibility: EMC immunity conforming to IEC 60947-4-1Emission tests criteria A conforming to IEC 60947-4-1Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3Voltage dips and interruptions immunity test conforming to SEMI F47
Connections - terminals: Power circuit: bar - busbar cross section: 32 x 10 mmPower circuit: lugs-ring terminals 1 240 mm²Control circuit: push-in 1 0.2...2.5 mm² - cable stiffness: solid stranded without cable endControl circuit: push-in 1 0.25...2.5 mm² - cable stiffness: flexible with cable endControl circuit: push-in 2 0.5...1.0 mm² with cable end
Tightening torque: 35 N.m
Mounting support: Direct on contactorPlate
Standards: EN/IEC 60947-4-1EN/IEC 60947-5-1UL 60947-4-1CSA C22.2 No 60947-4-1JIS C8201-4-1JIS C8201-5-1
Product certifications: CB SchemeCCCcULusUKCAATEXEU-RO-MR by DNV-GLEAC
In short
Reference LR9G500
Product Name Electronic thermal overload relay, TeSys Giga, 125…500 A, class 5E…30E, push-in control connection - LR9G500
Range TeSys
Related Categories