Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

Power base, TeSys U, 3P, 12A/690V - LUB12

LUB12

€49.44 Excl. Tax
€59.33 Inc. Tax
available In stock more than 100 units – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range of product: TeSys U
Range: TeSys
Product name: TeSys U
Device short name: LUB
Product or component type: Non reversing power base
Device application: Motor controlMotor protection
Poles description: 3P
Suitability for isolation: Yes
[Ue] rated operational voltage: 690 V AC for power circuit
Network frequency: 40...60 Hz
[Ith] conventional free air thermal current: 12 A
[Ie] rated operational current: 12 A at 12 A at 500 V9 A at 690 V
Utilisation category: AC-43AC-44AC-41
[Ics] rated service breaking capacity: 50 kA at 230 V50 kA at 440 V10 kA at 500 V4 kA at 690 V
Auxiliary contact composition: 1 NO + 1 NC
Auxiliary contacts type: type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1
[Uc] control circuit voltage: 24 V AC 50/60 Hz24 V DC48...72 V AC 50/60 Hz48...72 V DC110...240 V AC 50/60 Hz110...220 V DC
Typical current consumption: 130 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD140 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD150 mA at 24 V DC I maximum while closing with LUCM280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD35 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD60 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD70 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD70 mA at 24 V DC I rms sealed with LUCM
Heat dissipation: 2 W for control circuit with LUCA, LUCB, LUCC, LUCD1.7 W for control circuit with LUCM
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating time: 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit75 ms closing with LUCM for control circuit
Mechanical durability: 15 Mcycles
Maximum operating rate: 3600 cyc/h
Product certifications: CEULCSACCCEACASEFAATEXMarine
Standards: EN 60947-6-2IEC 60947-6-2UL 60947-4-1, with phase barrierCSA C22.2 No 60947-4-1, with phase barrier
[Ui] rated insulation voltage: 690 V conforming to IEC 60947-6-2 (pollution degree 3)600 V conforming to UL 60947-4-1600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Fixing mode: Clipped (DIN rail)Screw-fixed (plate)
Connections - terminals: Control circuit: screw clamp terminals 1 cable(s) 0.34...1.5 mm² flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 0.75...1.5 mm² flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 0.75...1.5 mm² rigidControl circuit: screw clamp terminals 2 cable(s) 0.34...1.5 mm² flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 0.75...1.5 mm² flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 0.75...1.5 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1...10 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1...6 mm² flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 2.5...10 mm² flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 1...6 mm² flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1...6 mm² rigidPower circuit: screw clamp terminals 2 cable(s) 1.5...6 mm² flexible without cable end
Tightening torque: Control circuit: 0.8...1.2 N.m flat screwdriver 5 mmControl circuit: 0.8...1.2 N.m Philips no 1 screwdriver 5 mmPower circuit: 1.9...2.5 N.m flat screwdriver 6 mmPower circuit: 1.9...2.5 N.m Philips No 2 screwdriver 6 mm
Width: 45 mm
Height: 154 mm
Depth: 126 mm
Product weight: 0.9 kg
Compatibility code: LUB
In short
Reference LUB12
Product Name Power base, TeSys U, 3P, 12A/690V - LUB12
Range TeSys
Device function Moteur
Related Categories