SCHNEIDER
Power base, TeSys U, 3P, 12A/690V - LUB12
LUB12
€49.44 Excl. Tax
€59.33 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock more than 100 units – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | TeSys U |
---|---|
Range: | TeSys |
Product name: | TeSys U |
Device short name: | LUB |
Product or component type: | Non reversing power base |
Device application: | Motor controlMotor protection |
Poles description: | 3P |
Suitability for isolation: | Yes |
[Ue] rated operational voltage: | 690 V AC for power circuit |
Network frequency: | 40...60 Hz |
[Ith] conventional free air thermal current: | 12 A |
[Ie] rated operational current: | 12 A at 12 A at 500 V9 A at 690 V |
Utilisation category: | AC-43AC-44AC-41 |
[Ics] rated service breaking capacity: | 50 kA at 230 V50 kA at 440 V10 kA at 500 V4 kA at 690 V |
Auxiliary contact composition: | 1 NO + 1 NC |
Auxiliary contacts type: | type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1 |
[Uc] control circuit voltage: | 24 V AC 50/60 Hz24 V DC48...72 V AC 50/60 Hz48...72 V DC110...240 V AC 50/60 Hz110...220 V DC |
Typical current consumption: | 130 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD140 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD150 mA at 24 V DC I maximum while closing with LUCM280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD35 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD35 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD60 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD70 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD70 mA at 24 V DC I rms sealed with LUCM |
---|---|
Heat dissipation: | 2 W for control circuit with LUCA, LUCB, LUCC, LUCD1.7 W for control circuit with LUCM |
Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Operating time: | 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit75 ms closing with LUCM for control circuit |
Mechanical durability: | 15 Mcycles |
Maximum operating rate: | 3600 cyc/h |
Product certifications: | CEULCSACCCEACASEFAATEXMarine |
Standards: | EN 60947-6-2IEC 60947-6-2UL 60947-4-1, with phase barrierCSA C22.2 No 60947-4-1, with phase barrier |
[Ui] rated insulation voltage: | 690 V conforming to IEC 60947-6-2 (pollution degree 3)600 V conforming to UL 60947-4-1600 V conforming to CSA C22.2 No 60947-4-1 |
[Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 60947-6-2 |
Safe separation of circuit: | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N |
Fixing mode: | Clipped (DIN rail)Screw-fixed (plate) |
Connections - terminals: | Control circuit: screw clamp terminals 1 cable(s) 0.34...1.5 mm² flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 0.75...1.5 mm² flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 0.75...1.5 mm² rigidControl circuit: screw clamp terminals 2 cable(s) 0.34...1.5 mm² flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 0.75...1.5 mm² flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 0.75...1.5 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1...10 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1...6 mm² flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 2.5...10 mm² flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 1...6 mm² flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1...6 mm² rigidPower circuit: screw clamp terminals 2 cable(s) 1.5...6 mm² flexible without cable end |
Tightening torque: | Control circuit: 0.8...1.2 N.m flat screwdriver 5 mmControl circuit: 0.8...1.2 N.m Philips no 1 screwdriver 5 mmPower circuit: 1.9...2.5 N.m flat screwdriver 6 mmPower circuit: 1.9...2.5 N.m Philips No 2 screwdriver 6 mm |
Width: | 45 mm |
Height: | 154 mm |
Depth: | 126 mm |
Product weight: | 0.9 kg |
Compatibility code: | LUB |