Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

circuit breaker Compact NSXm 63A 3P 16kA at 380/415V(IEC) EverLink lug - LV426105

LV426105

Obsolete product, here is the proposed substitution for the reference LV426105 : C11E3TM063L
Technical informations
Range: ComPact
Product name: ComPact NSXm
Range of product: ComPact NSXm
Device short name: NSXm 63E
Product or component type: Circuit breaker
Device application: ProtectionDistribution
Poles description: 3P
Protected poles description: 3D
[In] rated current: 63 A at 40 °C
[Ue] rated operational voltage: 690 V AC 50/60 Hz
Network type: AC
Network frequency: 50/60 Hz
Suitability for isolation: Yes conforming to EN/IEC 60947-2
Utilisation category: Category A
Breaking capacity: 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-216 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code: E 16 kA 415 V AC
Trip unit name: TM-D
Trip unit technology: Thermal-magnetic
Trip unit protection functions: LI
Control type: Toggle
Mounting mode: By screwsClip-on
[Ui] rated insulation voltage: 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage: 8 kV
[Ics] rated service breaking capacity: 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-216 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-210 kA at 440 V AC 50/60 Hz conforming to IEC 60947-28 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability: 20000 cycles
Electrical durability: 10000 cycles at 440 V In20000 cycles at 440 V In/25000 cycles at 690 V In10000 cycles at 690 V In/2
Mounting support: PlateDIN rail
Connections - terminals: 1 Everlink lug wire size 2.5...95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5...70 mm², flexible copper
Connection pitch: 35 mm with spreaders27 mm without spreaders
9 mm pitches: 9 module
Protection type: L
Trip unit rating: 63 A at 40 °C
Long time pick-up adjustment type Ir: Adjustable
Long time pick-up adjustment range: 0.7...1 x In
Long time delay adjustment type: Fixed
Magnetic tripping current: 800 A
Earth-leakage protection: Without
Number of slots: 1 slot(s) for auxiliary switch OF1 slot(s) for alarm switch SD1 slot(s) for voltage release MN or MX
Width: 81 mm
Height: 137 mm
Depth: 80 mm
Net weight: 1.06 kg
Colour: Grey (RAL 7016)
In short
Reference LV426105
Product Name circuit breaker Compact NSXm 63A 3P 16kA at 380/415V(IEC) EverLink lug - LV426105
Range Compact
Device function Distribution
Protection
Related Categories