Technical informations
Range: ComPact
Product name: ComPact NSXm
Range of product: ComPact NSXm
Device short name: NSXm 160E
Product or component type: Earth leakage circuit breaker
Device application: ProtectionDistribution
Poles description: 4P
Protected poles description: 4D
Neutral position: Left
[In] rated current: 160 A at 40 °C
[Ue] rated operational voltage: 440 V AC 50/60 Hz
Network type: AC
Network frequency: 50/60 Hz
Suitability for isolation: Yes conforming to EN/IEC 60947-2
Utilisation category: Category A
Breaking capacity: 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-216 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code: E 16 kA 415 V AC
Trip unit name: Micrologic 4.1
Trip unit technology: Electronic
Trip unit protection functions: LSoIR
Control type: Toggle
Mounting mode: By screwsClip-on
[Ui] rated insulation voltage: 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage: 8 kV
[Ics] rated service breaking capacity: 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-216 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-210 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability: 20000 cycles
Electrical durability: 10000 cycles at 440 V In20000 cycles at 440 V In/2
Mounting support: PlateDIN rail
Connections - terminals: 1 Everlink lug wire size 2.5...70 mm², fine stranded copper 1 Everlink lug wire size 2.5...95 mm², rigid or stranded aluminium/copper
Connection pitch: 35 mm with spreaders27 mm without spreaders
9 mm pitches: 12 module
Protection type: L
Trip unit rating: 160 A at 40 °C
Long time pick-up adjustment type Ir: Adjustable 9 settings
Long time pick-up adjustment range: 63...160 A
Long time delay adjustment type: Fixed
[tr] long-time delay adjustment range: 5 s at 7.2 x Ir8 s at 6 x Ir200 s at 1.5 x Ir
Thermal memory: 20 minutes before and after tripping
Short-time pick-up adjustment type Isd: Adjustable 9 settings
[Isd] short-time pick-up adjustment range: 1.5...10 x Ir
Short-time delay adjustment type: Fixed
[tsd] short-time delay adjustment range: 0.02 s
Instantaneous pick-up adjustment type Ii: Fixed
Instantaneous pick-up adjustment range: 2000 A
Earth-leakage protection: Integrated
Residual earth-leakage sensitity adjustment type: Adjustable
[I?n] residual earth-leakage sensitive adjustment: 0.03...5 A
Earth-leakage sensitivity: 30 mA for class A100 mA for class A300 mA for class A500 mA for class A1000 mA for class A30 mA for class AC100 mA for class AC300 mA for class AC500 mA for class AC1000 mA for class AC3000 mA for class AC5000 mA for class AC
Residual earth-leakage time delay adjustment type: Adjustable
[?t] residual earth-leakage time delay adjustment: 0 ms60 ms150 ms500 ms1000 ms
Neutral protection setting: No protection1 x Ir0.5 x Ir
Number of slots: 1 slot(s) for auxiliary switch OF1 slot(s) for alarm switch SD1 slot(s) for voltage release MN or MX
Local signalling: Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload
Width: 108 mm
Height: 144 mm
Depth: 80 mm
Net weight: 1.63 kg
Colour: Grey (RAL 7016)