Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
100 products at 10% off until 18 November! Find out more
SCHNEIDER

Circuit breaker ComPact NSX100F AC/DC, 18kA at 415VAC, TMD trip unit 80A, 2 poles 2d - LV438599

LV438599

Obsolete product, here is the proposed substitution for the reference LV438599 : C10F2TM080
Technical informations
Range: ComPact
Product name: ComPact NSX
Range of product: ComPact NSX100...250ComPact NSX100...250 DC
Device short name: NSX100F
Product or component type: Circuit breaker
Device application: Distribution
Poles description: 2P
Protected poles description: 2t
[In] rated current: 80 A at 40 °C
[Ue] rated operational voltage: 690 V AC 50/60 Hz500 V DC
Network type: DCAC
Network frequency: 50/60 Hz
Suitability for isolation: Yes conforming to EN/IEC 60947-2
Utilisation category: Category A
Breaking capacity: 5 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 250 V DC 1P conforming to IEC 60947-236 kA Icu at 125 V DC 1P conforming to IEC 60947-236 kA Icu at 500 V DC 2P conforming to IEC 60947-210 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-215 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-218 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code: F 18 kA 415 V AC
Trip unit name: TM-D
Trip unit technology: Thermal-magnetic
Control type: Toggle
Mounting mode: Fixed
[Ui] rated insulation voltage: 750 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2
[Ics] rated service breaking capacity: 5 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-236 kA at 250 V DC conforming to IEC 60947-236 kA at 125 V DC conforming to IEC 60947-236 kA at 500 V DC conforming to IEC 60947-210 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-215 kA at 440 V AC 50/60 Hz conforming to IEC 60947-218 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-236 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability: 20000 cycles
Electrical durability: 10000 cycles at 277 V In20000 cycles at 277 V In/2
Mounting support: Backplate
Upside connection: Front
Downside connection: Front
Connection pitch: 35 mm
Protection type: for overload protection (thermal) for short-circuit protection (magnetic)
Trip unit rating: 80 A at 40 °C
Long time pick-up adjustment type Ir: Fixed
Long time pick-up adjustment range: 1 In
Magnetic tripping current: 640 A
Earth-leakage protection: Without
Width: 70 mm
Height: 161 mm
Depth: 86 mm
Compatibility code: NSX100
In short
Reference LV438599
Product Name Circuit breaker ComPact NSX100F AC/DC, 18kA at 415VAC, TMD trip unit 80A, 2 poles 2d - LV438599
Range Compact
Device function Distribution
Related Categories