Technical informations
Range: PowerLogic
Product name: PowerLogic PM5000
Device short name: PM5561
Product or component type: Power meter
Market segment: Buildings small building cost management: billing: main incomerBuildings small building cost management: billing: sub feederBuildings medium building cost management: billing: main incomerBuildings medium building cost management: billing: sub feederBuildings large building cost management: billing: main incomerBuildings large building cost management: billing: sub feederBuildings multi-site cost management: billing: main incomerBuildings multi-site cost management: billing: sub feederData center cost management: billing: main incomerData center cost management: billing: sub feederHealthcare cost management: billing: main incomerHealthcare cost management: billing: sub feederIndustry cost management: billing: main incomerIndustry cost management: billing: sub feederBuildings small building cost management: cost allocation: main incomerBuildings small building cost management: cost allocation: sub feederBuildings medium building cost management: cost allocation: main incomerBuildings medium building cost management: cost allocation: sub feederBuildings large building cost management: cost allocation: main incomerBuildings large building cost management: cost allocation: sub feederBuildings multi-site cost management: cost allocation: main incomerBuildings multi-site cost management: cost allocation: sub feederData center cost management: cost allocation: main incomerData center cost management: cost allocation: sub feederHealthcare cost management: cost allocation: main incomerHealthcare cost management: cost allocation: sub feederIndustry cost management: cost allocation: main incomerIndustry cost management: cost allocation: sub feederBuildings small building network management: main incomerBuildings small building network management: sub feederBuildings medium building network management: main incomerBuildings medium building network management: sub feederBuildings large building network management: sub feederBuildings multi-site network management: sub feederData center network management: sub feederHealthcare network management: sub feederIndustry network management: sub feeder
Power quality analysis: up to the 63rd harmonic
Metering type: Measured neutral currentCalculated ground current
Device application: Multi-tariffWAGES meteringGatewayPower monitoring
Type of measurement: CurrentVoltageFrequencyPower factorEnergyActive and reactive power
[Us] rated supply voltage: 125...250 V DC100...480 V AC 45...65 Hz
Network frequency: 60 Hz50 Hz
[In] rated current: 5 A1 A
Poles description: 3P3P + N1P + N
Maximum power consumption in VA: 10 VA at 480 V
Ride-through time: 35 ms 120 V AC typical129 ms 230 V AC typical
Display type: Backlit LCD
Display resolution: 128 x 128 pixels
Sampling rate: 128 samples/cycle
Measurement current: 5...10000 mA
Analogue input type: Voltage (impedance 5 MOhm)Current (impedance 0.3 mOhm)
Measurement voltage: 20...400 V AC 45...65 Hz between phase and neutral20...690 V AC 45...65 Hz between phases
Frequency measurement range: 45...65 Hz
Number of inputs: 4 digital
Measurement accuracy: Apparent power +/- 0.5 %Frequency +/- 0.05 %Active energy +/- 0.2 %Reactive energy +/- 1 %Active power +/- 0.2 %Voltage +/- 0.1 %Power factor +/- 0.005Current +/- 0.15 °C
Accuracy class: Class 0.2S active energy conforming to IEC 62053-22
Number of outputs: 2 digital
Information displayed: Tariff (8)
Communication port protocol: Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 VJBUSModbus TCP/IP at 10/100 Mbit/s, insulation 2500 VEthernet Modbus TCP/IP daisy chainBACnet IP
Communication port support: RS485Ethernet
Communication gateway: Ethernet/serial
Data recording: Maintenance logsData logsAlarm logsEvent logsMin/max of instantaneous valuesTime stamping
Memory capacity: 1.1 MB
Web services: Alarm notification by e-mailWeb serverDiagnostic via predefined web pagesReal time viewing of data
Ethernet service: SNMP-TrapsSNTP client
Connections - terminals: Voltage circuit: screw terminal block4Control circuit: screw terminal block2Current transformer: screw terminal block6RS485 link: screw terminal block4Digital input: screw terminal block8Digital output: screw terminal block4Ethernet network: RJ45 connector2
Mounting mode: Flush-mounted
Mounting support: Framework
Standards: IEC 60529EN 50470-1UL 61010-1IEC 62053-24EN 50470-3IEC 62053-22IEC 61557-12ANSI C12.20
Product certifications: CE conforming to IEC 61010-1CULus conforming to UL 61010-1MID conforming to EN 50470-1MID conforming to EN 50470-3