Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
ABB

201M-C10 Miniature Circuit Breaker 10 - 1P - C - 10 A - ABB2CDS271001R0104

ABB2CDS271001R0104

€8.24 Excl. Tax
€9.89 Inc. Tax
available In stock more than 25 units – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 100€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations

Environmental

  • Ambient Air Temperature: Operation -25 ... +55 °C Storage -40 ... +70 °C
  • Reference Ambient Air Temperature: 30 °C
  • Degree of Protection: IP20 IP40 Enclosure with Cover IP40
  • Pollution Degree: 3
  • Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
  • Resistance to Vibrations: 20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
  • Resistance to Shock acc. to IEC 60068-2-27: 25g 2 shocks 13 ms

 Dimensions :

  • Width in Number of Modular Spacings: 1
  • Product Net Width: 17.5 mm
  • Product Net Height: 88 mm
  • Product Net Depth / Length: 69 mm
  • Product Net Weight: 0.125 kg
  • Pole Net Weight: 0.125 kg
  • Built-In Depth (t2): 69 mm

Certificates and Declarations

  • Certification Agency: EN : IE IEC

Technical :

  • Standards:
  • IEC/EN 60898-1 : CSA 22.2 No. 235
  • IEC/EN 60947-2 : UL 1077
  • Tripping Characteristic: : C
  • Rated Operational Voltage: : acc. to IEC 60898-1 230 / 400 V AC
  • acc. to IEC 60898-1 230 V : acc. to IEC 60947-2 230 V AC
  • Operational Voltage: : Maximum (Incl. Tolerance) 253 V AC
  • Maximum (Incl. Tolerance) 72 V DC : Minimum 12 V AC
  • Minimum 12 V DC : Rated Insulation Voltage (Ui):
  • acc. to IEC/EN 60664-1 440 V : Rated Impulse Withstand Voltage (Uimp):
  • 4 kV : at 2000 m 5 kV
  • at Sea Level 6.2 kV : Dielectric Test Voltage:
  • 50/60 Hz, 1 min: 2 kV : Input Voltage Type:
  • AC/DC : Rated Current (In):
  • 10 A : Rated Short-Circuit Capacity:
  • (AC) 10 kA : (230 / 400 V AC) 10 kA
  • (230 V) 10 kA : (400 V) 10 kA
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu): : (133 V AC) 25 kA
  • (230 V AC) 15 kA : (230 V) 15 kA
  • (400 V) 15 kA : Rated Conditional Short-Circuit Current (Inc):
  • (230 V) 15 kA : Rated Service Short-Circuit Breaking Capacity (Ics):
  • (133 V AC) 18.8 kA : (230 V AC) 7.5 kA
  • Frequency (f): : 50 Hz
  • Rated Frequency (f): : 50 / 60 Hz
  • Power Loss: : 2.1 W
  • at Rated Operating Conditions per Pole 2.1 W : Power Supply Connection:
  • Arbitrary : Contact Position Indication:
  • Red ON / Green OFF : Energy Limiting Class:
  • 3 : Electrical Endurance:
  • 20000 AC cycle : Mechanical Endurance:
  • 20000 cycle : Number of Protected Poles:
  • 1 : Number of Poles:
  • 1 : Overvoltage Category:
  • III : Tightening Torque:
  • 2.8 N·m : Screw Terminal Type:
  • Failsafe Bi-directional Cylinder-lift Terminal : Actuator Marking:
  • I / O : Actuator Material:
  • Insulation Group II, Black, Sealable : Housing Material:
  • Insulation Group II, RAL 7035 : Mounting on DIN Rail:
  • TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 : TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Mounting Position: : any
  • Recommended Screw Driver: : Pozidriv 2
  • Accessories Available: : Yes
  • Connecting Capacity: : Busbar 10 / 10 mm²
  • Flexible with Ferrule 0.75 ... 25 mm² : Flexible 0.75 ... 25 mm²
  • Flexible 0.75 ... 25 mm² : Rigid 0.75 ... 35 mm²
  • Rigid 0.75 ... 35 mm² : Stranded 0.75 ... 35 mm²
  • Installation Size: : acc. to DIN 43880 1
  • Terminal Type: : Screw Terminals

Technical UL/CSA :

  • Maximum Operating Voltage UL/CSA:
  • 60 V DC : 480Y/277 V AC
  • Interrupting Rating acc. to UL1077: : (277 V AC) 6 kA
  • (480Y / 277 V AC) 6 kA : (60 V DC) 10 kA
  • Connecting Capacity UL/CSA: : Busbar 14-8 AWG
  • Conductor 14-4 AWG : Tightening Torque UL/CSA:
  • 18 in·lb
In short
Reference ABB2CDS271001R0104
Product Name 201M-C10 Miniature Circuit Breaker 10 - 1P - C - 10 A - ABB2CDS271001R0104
Related Categories