Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews

Electrical Contactors

Reserved for professionals, TeSys electrical contactors from Schneider Electric are switching devices designed for…

LC2D09BD
SCHNEIDER
Contacteur inverseur TeSys LC2D 3P AC3 440V 9 A bobine 24 VCC - LC2D09BD
LC2D09BD
€151.74 €126.45
available In stock
dispatched within 24/48h
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 230 V AC coil - LC1D09P7
SCHNEIDER
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 230 V AC coil - LC1D09P7
LC1D09P7
€25.87 €21.56
available In stock
dispatched within 24/48h
LC1D09BD
SCHNEIDER
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V DC coil - LC1D09BD
LC1D09BD
€51.46 €42.88
available In stock
dispatched within 24/48h
TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 230 V AC coil  LC2D32P7
SCHNEIDER
TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 230 V AC coil - LC2D32P7
LC2D32P7
€229.30 €191.08
available In stock
dispatched within 24/48h
REVERSING CONTACTOR 575VAC 9A IEC  LC2D09B7
SCHNEIDER
REVERSING CONTACTOR 575VAC 9A IEC - LC2D09B7
LC2D09B7
€81.14 €67.62
available In stock
dispatched within 24/48h
TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 230 V AC coil  LC2D25P7
SCHNEIDER
TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 230 V AC coil - LC2D25P7
LC2D25P7
€160.82 €134.02
available In stock
dispatched within 24/48h
REVERSING CONTACTOR 575VAC 18A IEC  LC2D18BD
SCHNEIDER
REVERSING CONTACTOR 575VAC 18A IEC - LC2D18BD
LC2D18BD
€217.94 €181.62
available In stock
dispatched within 24/48h
LC2D09P7
SCHNEIDER
TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 230 V AC coil - LC2D09P7
LC2D09P7
€80.23 €66.86
available In stock
dispatched within 24/48h
Contacteur TeSys LC1-D - 3 pôles - CA-3 440&nbsp - V 65 A - bobine 230 V CA LC1D65AP7
SCHNEIDER
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 230 V AC 50/60 Hz coil - LC1D65AP7
LC1D65AP7
€172.82 €144.02
available In stock
dispatched within 24/48h
LC1DT80AP7
SCHNEIDER
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 230 V AC 50/60 Hz coil - LC1DT80AP7
LC1DT80AP7
€244.64 €203.87
available In stock
dispatched within 24/48h
LC1D32P7
SCHNEIDER
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 230 V AC 50/60 Hz coil - LC1D32P7
LC1D32P7
€81.84 €68.20
available In stock
dispatched within 24/48h
LC1D25P7
LC1D25P7
€60.20 €50.17
available In stock
dispatched within 24/48h
LC2D25BD REVERSING CONTACTOR 575VAC 25A IEC 
SCHNEIDER
REVERSING CONTACTOR 575VAC 25A IEC - LC2D25BD
LC2D25BD
€250.81 €209.01
available In stock
dispatched within 24/48h
LC1D115004P7
SCHNEIDER
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 200 A - 230 V AC 50/60 Hz coil - LC1D115004P7
LC1D115004P7
€489.67 €408.06
available In stock
dispatched within 24/48h
LC1D150P7
SCHNEIDER
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 230 V AC 50/60 Hz coil - LC1D150P7
LC1D150P7
€408.77 €340.64
available In stock
dispatched within 24/48h
Contacteur TeSys LC1-D - 3P - AC-3 440V 18 A - bobine 24 V CC LC1D18BD
LC1D18BD
€73.07 €60.89
available In stock
dispatched within 24/48h

What is an industrial electrical contactor?

A contactor is an electromagnetic relay that opens or closes a circuit upon receiving an electrical signal. With their high breaking capacity, industrial contactors, when installed in electrical panels, are used to power small, medium, and large motors (over 0.5 kW).

When properly sized, they ensure correct motor starting and optimal operation. The aim is to enhance reliability and motor longevity while ensuring uninterrupted service.

Single-pole, double-pole, 3-pole or 4-pole contactors, with 1 to 4 contacts, can be controlled by AC or DC voltages from 24 V to 400 V.

Good to know: The auxiliary contactor is used in the control section of electrical circuits with low currents (as opposed to the power section). It has no power contact and is mainly used to pass data from the circuit to a logic controller using NO (normally open) contacts and NC (normally closed) contacts. Are you looking for a Schneider motor contactor or auxiliary contactor? Opt for One-elec.com!

What's the difference between the main contactor and an auxiliary contactor?

Although they are both used to operate one or more contacts to transfer the power supply to a piece of equipment, their operation depends on the current loads and switching voltages, which can be very high.

The main contactor or simply contactor is used when the power of the load to be controlled is greater than the power that can be controlled by the element itself. In other words, a contactor is dimensioned to withstand the occurrence of an electric arc resulting from a high current, on opening or closing the circuit, such as a resistor, a motor or other high-power receivers.

The auxiliary contactor is used in the control section of electrical circuits where currents remain low (as opposed to the power section). It has no power contact and is mainly used to control NO (normally open) contacts and NC (normally closed) contacts.

Schneider Electric TeSys auxiliary contactors

TeSys K and TeSys D auxiliary contactors are designed to control low-power auxiliary circuits and relay power contactors.

Suitable for controlling three-phase motors up to 7.5 kW and resistive loads, these contactors come in reversing or non-reversing options and incorporate up to 5 auxiliary contacts with 4 only for the Tesys K.

Tesys K contactors are available to control up to 16 A (AC-3) and Tesys D contactors control up to 150 A (AC-3).

What do AC1 and AC3 categories mean for TeSys auxiliary contactors?

These 2 utilisation categories are standardised for alternating current and set the current values that the contactor can open or close, taking into account the type of load to be controlled and the power cycle conditions.

Category AC-1 applies to all devices with a cos > 0.95 including resistive loads, ovens, lighting circuits, heating circuits, and distribution circuits.

The AC-3 category is more commonly used with three-phase asynchronous motors where disconnection takes place with the motor running, such as lifts, escalators, conveyors, bucket lifts, compressors, pumps, mixers or air conditioners.

Schneider Electric TeSys contactors

Unlike auxiliary contactors, these main contactors are designed to open or close high-power electrical circuits.

The TeSys K and TeSys Deca (formerly TeSys D) power contactors are used in the industrial sector.

TeSys Deca is for power ratings up to 75 kW and TeSys K for power ratings up to 7.5 kW.

How do I test the continuity of a contactor's contacts and coil?

Start by testing the coil by testing its resistance at the input and output terminals of the contactor with an ohmmeter. If you don't detect any value, the coil is damaged. Remember to set the tester in mode 1 (forced operation).

For NO contacts, when they are not working, the resistance must be infinite; when they are working, the resistance must be "zero".

For NC contacts, when not operating, the resistance must be "zero"; when operating, the resistance must be infinite.

The accessories available for the TeSys contactor range

  • Electrical interlocks
  • Kits for changeover contactors
  • Kits for assembling changeover contactors
  • Connection sets
  • Mechanical interlock blocks
  • Auxiliary contact blocks with serrated wiping action
  • Dust-tight front-mounted auxiliary contact blocks
  • Pneumatic timers
  • Transient voltage suppressors
  • Interface modules and electronic timers

Can't find the accessory you need? Leave us a message!