Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

circuit breaker VigiComPact NSX160F, 36 kA at 415 VAC, TM-D trip unit 125 A, add-on Vigi MH module, 4P 4d - LV430951

LV430951

Obsolete product, here is the list of products that can replace the reference LV430951 :
  • C16F44V160
  • C12F44V160L
  • Technical informations
    Range: ComPact
    Product name: ComPact NSX
    Range of product: ComPact NSX100...250
    Device short name: VigiCompact NSX160F
    Product or component type: Circuit breaker with Vigi add-on
    Device application: Distribution
    Poles description: 4P
    Protected poles description: 4t
    Neutral position: Left
    [In] rated current: 125 A at 40 °C
    [Ue] rated operational voltage: 440 V AC 50/60 Hz
    Network type: AC
    Network frequency: 50/60 Hz
    Suitability for isolation: Yes conforming to EN/IEC 60947-2
    Utilisation category: Category A
    Breaking capacity: 10 kA at 600 V AC 50/60 Hz conforming to UL 50885 kA at 240 V AC 50/60 Hz conforming to UL 50822 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-235 kA at 480 V AC 50/60 Hz conforming to UL 50830 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    Breaking capacity code: F 36 kA 415 V AC
    Trip unit name: TM-D
    Trip unit technology: Thermal-magnetic
    Trip unit protection functions: LI
    Control type: Toggle
    Mounting mode: Fixed
    [Ui] rated insulation voltage: 800 V AC 50/60 Hz
    [Uimp] rated impulse withstand voltage: 8 kV
    [Ics] rated service breaking capacity: 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-285 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-222 kA at 525 V AC 50/60 Hz conforming to IEC 60947-230 kA at 500 V AC 50/60 Hz conforming to IEC 60947-28 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
    Mechanical durability: 40000 cycles
    Electrical durability: 7500 cycles at 690 V In15000 cycles at 690 V In/220000 cycles at 440 V In40000 cycles at 440 V In/2
    Mounting support: Backplate
    Upside connection: Front
    Downside connection: Front
    Connection pitch: 35 mm
    Protection type: L
    Trip unit rating: 125 A at 40 °C
    Long time pick-up adjustment type Ir: Adjustable
    Long time pick-up adjustment range: 0.7...1 x In
    Long time delay adjustment type: Fixed
    [tr] long-time delay adjustment range: 120...400 s at 1.5 x In15 s at 6 x Ir
    Short-time pick-up adjustment type Isd: Fixed
    [Isd] short-time pick-up adjustment range: 1250 A
    Short-time delay adjustment type: Fixed
    Earth-leakage protection: With
    Earth-leakage add-on module name: MH
    Earth-leakage protection class: Class A
    Residual earth-leakage sensitity adjustment type: Adjustable 5 settings
    [I?n] residual earth-leakage sensitive adjustment: 0.03...10 A
    Residual earth-leakage time delay adjustment type: Adjustable 4 settings
    Neutral protection setting: 1 x Ir (4t)
    Number of slots: 6 slot(s)
    Width: 140 mm
    Height: 236 mm
    Depth: 86 mm
    Product weight: 2.6 kg
    Compatibility code: NSX160
    In short
    Reference LV430951
    Product Name circuit breaker VigiComPact NSX160F, 36 kA at 415 VAC, TM-D trip unit 125 A, add-on Vigi MH module, 4P 4d - LV430951
    Range Compact
    Device function Distribution
    Related Categories