SCHNEIDER
module XPSAC - Emergency stop - 24 V AC DC - XPSAC5121P
XPSAC5121P
Product not available. Here is the equivalent reference that we offer: XPSBAC14AP - Estop or guard ,Harmony XPS, connected to supply terminals 24 V AC/DC , no inputs, screw
Technical informations
Range of product: | Preventa Safety automation |
---|---|
Product or component type: | Preventa safety module |
Safety module name: | XPSAC |
Safety module application: | For emergency stop and switch monitoring |
Function of module: | Switch monitoringEmergency stop |
Safety level: | Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061 |
Safety reliability data: | MTTFd = 210.4 years conforming to EN/ISO 13849-1DC > 99 % conforming to EN/ISO 13849-1PFHd = 3.56E-9 1/h conforming to EN/IEC 62061 |
Type of start: | Unmonitored |
Connections - terminals: | Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
Output type: | Relay instantaneous opening, 3 NO circuit(s), volt-free |
Number of additional circuits: | 1 solid state output |
[Us] rated supply voltage: | 24 V AC - 20...10 %24 V DC - 20...20 % |
Supply frequency: | 50/60 Hz |
---|---|
Maximum power consumption in W: | 1.2 W DC |
Maximum power consumption in VA: | 2.5 VA AC |
[Uc] control circuit voltage: | 24 V |
Breaking capacity: | 180 VA holding AC-15 C300 relay output1800 VA inrush AC-15 C300 relay output |
Breaking capacity: | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output |
Output thermal current: | 6 A per relay for relay output |
[Ith] conventional free air thermal current: | 10.5 A |
Associated fuse rating: | 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 2006 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
Minimum output current: | 10 mA for relay output |
Minimum output voltage: | 16 V for relay output |
Maximum response time on input open: | 100 ms |
[Ui] rated insulation voltage: | 300 V (pollution degree 2) conforming to IEC 60947-5-1300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 |
[Uimp] rated impulse withstand voltage: | 4 kV overvoltage category III conforming to IEC 60947-5-14 kV overvoltage category III conforming to DIN VDE 0110 part 1 |
Local signalling: | 2 LEDs |
Current consumption: | 40 mA at 24 V DC on power supply90 mA at 24 V AC on power supply |
Mounting support: | 35 mm symmetrical DIN rail |
Product weight: | 0.16 kg |
In short