SCHNEIDER
Motor circuit breaker, TeSys GV6, 3P, 500A, Icu 36kA, thermal magnetic - GV6P500F
GV6P500F
€1,576.92 Excl. Tax
€1,892.30 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | TeSys |
---|---|
Range of product: | TeSys GV6 |
Product name: | TeSys GV6 |
Product or component type: | Motor circuit breaker |
Device short name: | GV6P |
Device application: | Motor protection |
Protection type: | Overload protectionShort-circuit protectionInstantaneous short-circuit protectionPhase unbalancePhase loss |
Utilisation category: | Category A conforming to IEC 60947-2 |
Control type: | Direct rotary handle |
Suitability for isolation: | Yes conforming to EN/IEC 60947-2 |
Poles description: | 3P |
[Ue] rated operational voltage: | 690 V AC 50/60 Hz |
[In] rated current: | 500 A at 65 °C |
Breaking capacity code: | F 36 kA |
Breaking capacity: | 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ics] rated service short-circuit breaking capacity: | 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2100 % at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ui] rated insulation voltage: | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
[Uimp] rated impulse withstand voltage: | 8 kV |
Overvoltage category: | III |
Trip unit name: | Micrologic 2.3 M |
Trip unit rating: | 500 A |
Trip unit technology: | Electronic |
Magnetic tripping current: | 6500 A |
[Isd] short-time pick-up adjustment range: | 5...13 x Ir adjustable 9 settings |
Thermal protection adjustment range: | 250...500 A adjustable 9 settings |
Thermal overload class: | Class 5 conforming to IEC 60947-4-1Class 10 conforming to IEC 60947-4-1Class 20 conforming to IEC 60947-4-1 |
Phase failure sensitivity: | Yes conforming to IEC 60947-4-1 |
Mechanical durability: | 15000 cycles |
Electrical durability: | 4000 cycles for AC-3 at 400/415 V In |
Maximum operating rate: | 25 cyc/h |
Rated duty: | Continuous |
Power dissipation per pole: | 39.7 W |
Motor power kW: | 200...250 kW at 400/415 V AC 50/60 Hz250...315 kW at 500 V AC 50/60 Hz315...400 kW at 660/690 V AC 50/60 Hz |
---|---|
Local signalling: | LED readyLED 95 % Ith |
Standards: | EN/IEC 60947-1EN/IEC 60947-2EN/IEC 60947-4-1UL 60947-4-1CSA C22.2 No 60947-4-1 |
Product certifications: | IECEE CB SchemeEAC (pending) |
Fixing mode: | By screws |
Mounting position: | Horizontal and vertical |
Connections - terminals: | Power circuit: bars - busbar cross section: 32 x 10 mmPower circuit: lugs - external diameter: 32 mm |
Connection pitch: | 45 mm without spreaders |
Tightening torque: | 50 N.m screw |
Width: | 140 mm |
Height: | 255 mm |
Depth: | 179 mm |
Product weight: | 6.7 kg |
Colour: | Anthracite (RAL 7016) |
In short
Reference GV6P500F
Product Name Motor circuit breaker, TeSys GV6, 3P, 500A, Icu 36kA, thermal magnetic - GV6P500F
Range TeSys
Device function Motor protection
Related Categories