Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

Motor circuit breaker, TeSys GV6, 3P, 500A, Icu 36kA, thermal magnetic - GV6P500F

GV6P500F

€1,576.92 Excl. Tax
€1,892.30 Inc. Tax
available In stock – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range: TeSys
Range of product: TeSys GV6
Product name: TeSys GV6
Product or component type: Motor circuit breaker
Device short name: GV6P
Device application: Motor protection
Protection type: Overload protectionShort-circuit protectionInstantaneous short-circuit protectionPhase unbalancePhase loss
Utilisation category: Category A conforming to IEC 60947-2
Control type: Direct rotary handle
Suitability for isolation: Yes conforming to EN/IEC 60947-2
Poles description: 3P
[Ue] rated operational voltage: 690 V AC 50/60 Hz
[In] rated current: 500 A at 65 °C
Breaking capacity code: F 36 kA
Breaking capacity: 36 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity: 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2100 % at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage: 800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
Trip unit name: Micrologic 2.3 M
Trip unit rating: 500 A
Trip unit technology: Electronic
Magnetic tripping current: 6500 A
[Isd] short-time pick-up adjustment range: 5...13 x Ir adjustable 9 settings
Thermal protection adjustment range: 250...500 A adjustable 9 settings
Thermal overload class: Class 5 conforming to IEC 60947-4-1Class 10 conforming to IEC 60947-4-1Class 20 conforming to IEC 60947-4-1
Phase failure sensitivity: Yes conforming to IEC 60947-4-1
Mechanical durability: 15000 cycles
Electrical durability: 4000 cycles for AC-3 at 400/415 V In
Maximum operating rate: 25 cyc/h
Rated duty: Continuous
Power dissipation per pole: 39.7 W
Motor power kW: 200...250 kW at 400/415 V AC 50/60 Hz250...315 kW at 500 V AC 50/60 Hz315...400 kW at 660/690 V AC 50/60 Hz
Local signalling: LED readyLED 95 % Ith
Standards: EN/IEC 60947-1EN/IEC 60947-2EN/IEC 60947-4-1UL 60947-4-1CSA C22.2 No 60947-4-1
Product certifications: IECEE CB SchemeEAC (pending)
Fixing mode: By screws
Mounting position: Horizontal and vertical
Connections - terminals: Power circuit: bars - busbar cross section: 32 x 10 mmPower circuit: lugs - external diameter: 32 mm
Connection pitch: 45 mm without spreaders
Tightening torque: 50 N.m screw
Width: 140 mm
Height: 255 mm
Depth: 179 mm
Product weight: 6.7 kg
Colour: Anthracite (RAL 7016)
In short
Reference GV6P500F
Product Name Motor circuit breaker, TeSys GV6, 3P, 500A, Icu 36kA, thermal magnetic - GV6P500F
Range TeSys
Device function Motor protection
Related Categories