SCHNEIDER
TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC low - LC1K06016BLS207
LC1K06016BLS207
€39.58 Excl. Tax
€47.50 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 100€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | TeSys K |
---|---|
Range: | TeSys |
Product or component type: | Contactor |
Product name: | TeSys K |
Device short name: | LC1K |
Device application: | Control |
Contactor application: | Motor controlResistive load |
Utilisation category: | AC-3AC-1 |
---|---|
Poles description: | 3P |
Pole contact composition: | 3 NO |
[Ue] rated operational voltage: | Power circuit: 690 V AC 50/60 HzSignalling circuit: |
[Ie] rated operational current: | 6 A at |
Control circuit type: | DC low consumption |
[Uc] control circuit voltage: | 24 V DC |
Motor power kW: | 1.5 kW at 220...230 V AC 50/60 Hz2.2 kW at 380...415 V AC 50/60 Hz3 kW at 500...600 V AC 50/60 Hz3 kW at 440/500 V AC 50/60 Hz3 kW at 660/690 V AC 50/60 Hz0.37 kW at 115 V AC 50/60 Hz0.75 kW at 220 V AC 50/60 Hz |
Auxiliary contact composition: | 1 NC |
[Uimp] rated impulse withstand voltage: | 8 kV |
Overvoltage category: | III |
[Ith] conventional free air thermal current: | 20 A (at 50 °C) for power circuit10 A (at 50 °C) for signalling circuit |
Irms rated making capacity: | 110 A AC for power circuit conforming to NF C 63-110110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947 |
Rated breaking capacity: | 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
[Icw] rated short-time withstand current: | 90 A 50 °C - 1 s for power circuit85 A 50 °C - 5 s for power circuit80 A 50 °C - 10 s for power circuit60 A 50 °C - 30 s for power circuit45 A 50 °C - 1 min for power circuit40 A 50 °C - 3 min for power circuit20 A 50 °C - >= 15 min for power circuit80 A - 1 s for signalling circuit90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit |
Associated fuse rating: | 25 A gG at 10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660 |
Average impedance: | 3 mOhm - Ith 20 A 50 Hz for power circuit |
[Ui] rated insulation voltage: | Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Power circuit: 750 V conforming to VDE 0110 group CPower circuit: 690 V conforming to BS 5424Power circuit: 690 V conforming to NF C 20-040 |
Insulation resistance: | > 10 MOhm for signalling circuit |
Inrush power in W: | 1.8 W (at 20 °C) |
Hold-in power consumption in W: | 1.8 W at 20 °C |
Heat dissipation: | 1.8 W |
Control circuit voltage limits: | Operational: 0.7...1.3 Uc (at Drop-out: >= 0.10 Uc (at |
Connections - terminals: | Power circuit: lugs-ring terminals (external diameter: 7 mm) |
Maximum operating rate: | 3600 cyc/h |
Coil technology: | With integral suppression device |
Auxiliary contacts type: | type instantaneous 1 NC |
Signalling circuit frequency: | |
Minimum switching current: | 5 mA for signalling circuit |
Minimum switching voltage: | 17 V for signalling circuit |
Mounting support: | RailPlate |
Tightening torque: | Power circuit: 1.3 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm3.2 mmPower circuit: 1.3 N.m - on lugs-ring terminals - with screwdriver Philips No 23.2 mm |
Operating time: | 10...20 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing |
Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Non overlap distance: | 0.5 mm |
Mechanical durability: | 30 Mcycles |
Electrical durability: | 1.3 Mcycles 6 A AC-3 at Ue |
Mechanical robustness: | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
Height: | 58 mm |
Width: | 45 mm |
Depth: | 57 mm |
Product weight: | 0.235 kg |
In short
Reference LC1K06016BLS207
Product Name TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC low - LC1K06016BLS207