Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
⚠️ WE ARE CLOSED ON 01/11: Final shipments will be dispatched by 31/10, with shipping resuming on 04/11 ⚠️
SCHNEIDER

TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC low - LC1K06016BLS207

LC1K06016BLS207

€39.58 Excl. Tax
€47.50 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 100€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range of product: TeSys K
Range: TeSys
Product or component type: Contactor
Product name: TeSys K
Device short name: LC1K
Device application: Control
Contactor application: Motor controlResistive load
Utilisation category: AC-3AC-1
Poles description: 3P
Pole contact composition: 3 NO
[Ue] rated operational voltage: Power circuit: 690 V AC 50/60 HzSignalling circuit:
[Ie] rated operational current: 6 A at
Control circuit type: DC low consumption
[Uc] control circuit voltage: 24 V DC
Motor power kW: 1.5 kW at 220...230 V AC 50/60 Hz2.2 kW at 380...415 V AC 50/60 Hz3 kW at 500...600 V AC 50/60 Hz3 kW at 440/500 V AC 50/60 Hz3 kW at 660/690 V AC 50/60 Hz0.37 kW at 115 V AC 50/60 Hz0.75 kW at 220 V AC 50/60 Hz
Auxiliary contact composition: 1 NC
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 20 A (at 50 °C) for power circuit10 A (at 50 °C) for signalling circuit
Irms rated making capacity: 110 A AC for power circuit conforming to NF C 63-110110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity: 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current: 90 A 50 °C - 1 s for power circuit85 A 50 °C - 5 s for power circuit80 A 50 °C - 10 s for power circuit60 A 50 °C - 30 s for power circuit45 A 50 °C - 1 min for power circuit40 A 50 °C - 3 min for power circuit20 A 50 °C - >= 15 min for power circuit80 A - 1 s for signalling circuit90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit
Associated fuse rating: 25 A gG at 10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660
Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage: Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Power circuit: 750 V conforming to VDE 0110 group CPower circuit: 690 V conforming to BS 5424Power circuit: 690 V conforming to NF C 20-040
Insulation resistance: > 10 MOhm for signalling circuit
Inrush power in W: 1.8 W (at 20 °C)
Hold-in power consumption in W: 1.8 W at 20 °C
Heat dissipation: 1.8 W
Control circuit voltage limits: Operational: 0.7...1.3 Uc (at Drop-out: >= 0.10 Uc (at
Connections - terminals: Power circuit: lugs-ring terminals (external diameter: 7 mm)
Maximum operating rate: 3600 cyc/h
Coil technology: With integral suppression device
Auxiliary contacts type: type instantaneous 1 NC
Signalling circuit frequency:
Minimum switching current: 5 mA for signalling circuit
Minimum switching voltage: 17 V for signalling circuit
Mounting support: RailPlate
Tightening torque: Power circuit: 1.3 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm3.2 mmPower circuit: 1.3 N.m - on lugs-ring terminals - with screwdriver Philips No 23.2 mm
Operating time: 10...20 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance: 0.5 mm
Mechanical durability: 30 Mcycles
Electrical durability: 1.3 Mcycles 6 A AC-3 at Ue
Mechanical robustness: Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Height: 58 mm
Width: 45 mm
Depth: 57 mm
Product weight: 0.235 kg
In short
Reference LC1K06016BLS207
Product Name TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC low - LC1K06016BLS207
Related Categories