SCHNEIDER
TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil - LC3D80B7
LC3D80B7
€1,697.11 Excl. Tax
€2,036.53 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | TeSys D |
---|---|
Range: | TeSys |
Product name: | TeSys D |
Product or component type: | Star delta starter |
Device short name: | LC3D |
Contactor application: | Motor control |
Utilisation category: | AC-3 |
Device presentation: | Pre-wired |
Poles description: | 3 x 3P |
Pole contact composition: | 3 x 3 NO |
[Ue] rated operational voltage: | Power circuit: |
[Ie] rated operational current: | 80 A (at |
Motor power kW: | 37 kW at 220/230 V AC 50/60 Hz75 kW at 380/400 V AC 50/60 Hz75 kW at 415 V AC 50/60 Hz75 kW at 440 V AC 50/60 Hz |
Control circuit type: | AC at 50/60 Hz |
[Uc] control circuit voltage: | 24 V AC 50/60 Hz |
Auxiliary contact composition: | 1 NC for KM2 line contactor1 NO for KM3 delta contactor |
[Uimp] rated impulse withstand voltage: | 8 kV conforming to IEC 60947 |
Overvoltage category: | III |
[Ui] rated insulation voltage: | Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certifiedPower circuit: 1000 V conforming to IEC 60947-4-1Signalling circuit: 1000 V conforming to IEC 60947-1 |
Electrical durability: | 10 Mcycles 80 A AC-3 at Ue |
Mounting support: | Plate |
Standards: | EN 60947-4-1CSA C22.2 No 14EN 60947-5-1IEC 60947-4-1UL 508IEC 60947-5-1 |
Product certifications: | GLCCCULGOSTLROS (Lloyds register of shipping)CSADNVRINABV |
Connections - terminals: | Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 1 4...50 mm² - cable stiffness: flexible without cable endPower circuit: screw clamp terminals 2 4...25 mm² - cable stiffness: flexible without cable endPower circuit: screw clamp terminals 1 4...50 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 4...16 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 1 4...50 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 4...25 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 1 1...2.5 mm² - cable stiffness: flexible with cable end |
---|---|
Tightening torque: | Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 12 N.m - on screw clamp terminals - with screwdriver flat Ø 6...8 mm |
Mechanical durability: | 4 Mcycles |
Maximum operating rate: | 30 cyc/h 60 °C |
Starting time: | 30 s |
Coil technology: | Without built-in suppressor module |
Control circuit voltage limits: | Drop-out: 0.3...0.6 Uc at 50/60 Hz (at Operational: 0.8...1.1 Uc at 50 Hz (at Operational: 0.85...1.1 Uc at 60 Hz (at |
Inrush power in VA: | 140 VA 60 Hz cos phi 0.75 (at 20 °C)160 VA 50 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA: | 13 VA 60 Hz cos phi 0.3 (at 20 °C)15 VA 50 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation: | 4...5 W at 50/60 Hz |
Auxiliary contacts type: | Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NCMirror contact conforming to IEC 60947-4-1 3 x 1 NC |
Signalling circuit frequency: | 25...400 Hz |
Minimum switching current: | 5 mA for signalling circuit |
Switching voltage: | 17 V for signalling circuit |
Non-overlap time: | 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact |
Width: | 311 mm |
Height: | 143 mm |
Depth: | 183 mm |
Product weight: | 5.2 kg |
Power range: | 30...50 kW at 200...240 V 3 phases55...100 kW at 380...440 V 3 phases15...25 kW at 200...240 V 3 phases30...50 kW at 380...440 V 3 phases |
Motor starter type: | Star delta starter |
Contactor coil voltage: | 24 V AC standard |
In short
Reference LC3D80B7
Product Name TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil - LC3D80B7
Range TeSys
Related Categories