SCHNEIDER
TeSys LRD thermal overload relays - 37...50 A - class 10A - LR3D350
LR3D350
€90.51 Excl. Tax
€108.61 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | TeSysTeSys Deca |
---|---|
Product name: | TeSys LRDTeSys Deca |
Product or component type: | Non differential thermal overload relay |
Device short name: | LR3D |
Relay application: | Motor protection |
Product compatibility: | LC1D40ALC1D50ALC1D65A |
Network type: | DCAC |
Thermal overload class: | Class 10A conforming to IEC 60947-4-1 |
Thermal protection adjustment range: | 37...50 A |
[Ui] rated insulation voltage: | Power circuit: 600 V conforming to CSAPower circuit: 600 V conforming to ULPower circuit: 690 V conforming to IEC 60947-4-1 |
Network frequency: | 0...400 Hz |
---|---|
Mounting support: | Plate, with specific accessoriesRail, with specific accessoriesUnder contactor |
Tripping threshold: | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
Auxiliary contact composition: | 1 NO + 1 NC |
[Ith] conventional free air thermal current: | 5 A for signalling circuit |
Permissible current: | 0.95 A at 380 V AC-15 for signalling circuit0.06 A at 440 V DC-13 for signalling circuit |
[Ue] rated operational voltage: | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
Associated fuse rating: | 4 A gG for signalling circuit4 A BS for signalling circuit |
[Uimp] rated impulse withstand voltage: | 6 kV |
Phase failure sensitivity: | Tripping current 130 % of Ir on two phase, the last one at 0 |
Control type: | Red push-button: stopBlue push-button: reset |
Temperature compensation: | -20...60 °C |
Connections - terminals: | Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² solid without cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1...35 mm² flexible without cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1...35 mm² flexible with cable endPower circuit: EverLink BTR screw connectors 1 cable(s) 1...35 mm² solid without cable end |
Tightening torque: | Control circuit: 1.7 N.m - on screw clamp terminalsPower circuit: 5 N.m - on EverLink BTR screw connectors |
Height: | 70 mm |
Width: | 55 mm |
Depth: | 123 mm |
Product weight: | 0.375 kg |
Compatibility code: | LR3D |
In short
Reference LR3D350
Product Name TeSys LRD thermal overload relays - 37...50 A - class 10A - LR3D350
Range TeSys
Related Categories