Range of product: Modicon M221
Product or component type: Logic controller
[Us] rated supply voltage: 100...240 V AC
Discrete input number: 14, discrete input conforming to IEC 61131-2 Type 1
Analogue input number: 2 at 0...10 V
Discrete output type: Relay normally open
Discrete output number: 10 relay
Discrete output voltage: 5...125 V DC5...250 V AC
Discrete output current: 2 A
Discrete I/O number: 24
Maximum number of I/O expansion module: 7 for transistor output7 for relay output
Supply voltage limits: 85...264 V
Network frequency: 50/60 Hz
Inrush current: 40 A
Maximum power consumption in VA: 58 VA at 100...240 V with max number of I/O expansion module35 VA at 100...240 V without I/O expansion module
Power supply output current: 0.52 A 5 V for expansion bus0.16 A 24 V for expansion bus
Discrete input logic: Sink or source (positive/negative)
Discrete input voltage: 24 V
Discrete input voltage type: DC
Analogue input resolution: 10 bits
LSB value: 10 mV
Conversion time: 1 ms per channel + 1 controller cycle time for analogue input analog input
Permitted overload on inputs: +/- 30 V DC for 5 min (maximum) for analog input+/- 13 V DC (permanent) for analog input
Voltage state 1 guaranteed: >= 15 V for input
Voltage state 0 guaranteed:
Discrete input current: 7 mA for discrete input5 mA for fast input
Input impedance: 3.4 kOhm for discrete input100 kOhm for analog input4.9 kOhm for fast input
Response time: 35 µs turn-off, I2...I5 terminal(s) for input10 ms turn-on for output10 ms turn-off for output5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input35 µs turn-on, other terminals terminal(s) for input5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input100 µs turn-off, other terminals terminal(s) for input
Configurable filtering time: 0 ms for input3 ms for input12 ms for input
Output voltage limits: 125 V DC277 V AC
Maximum current per output common: 4 A at COM 27 A at COM 07 A at COM 1
Absolute accuracy error: +/- 1 % of full scale for analog input
Electrical durability: 100000 cycles AC-12, 120 V, 240 VA, resistive100000 cycles AC-12, 240 V, 480 VA, resistive300000 cycles AC-12, 120 V, 80 VA, resistive300000 cycles AC-12, 240 V, 160 VA, resistive100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive100000 cycles DC-12, 24 V, 48 W, resistive300000 cycles DC-12, 24 V, 16 W, resistive100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Switching frequency: 20 switching operations/minute with maximum load
Mechanical durability: 20000000 cycles for relay output
Minimum load: 1 mA at 5 V DC for relay output
Protection type: Without protection at 5 A
Reset time: 1 s
Memory capacity: 256 kB for user application and data RAM with 10000 instructions256 kB for internal variables RAM
Data backed up: 256 kB built-in flash memory for backup of application and data
Data storage equipment: 2 GB SD card (optional)
Battery type: BR2032 lithium non-rechargeable, battery life: 4 year(s)
Backup time: 1 year at 25 °C (by interruption of power supply)
Execution time for 1 KInstruction: 0.3 ms for event and periodic task
Execution time per instruction: 0.2 µs Boolean
Exct time for event task: 60 µs response time
Maximum size of object areas: 255 %TM timers512 %M memory bits8000 %MW memory words255 %C counters512 %KW constant words
Realtime clock: With
Clock drift:
Regulation loop: Adjustable PID regulator up to 14 simultaneous loops
Counting input number: 4 fast input (HSC mode) at 100 kHz 32 bits
Control signal type: A/BSingle phasePulse/direction
Integrated connection type: USB port with mini B USB 2.0 connectorNon isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface Ethernet with RJ45 connector
Supply: (serial)serial link supply: 5 V,
Transmission rate: 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS4851.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232480 Mbit/s for USB
Communication port protocol: USB port: USB - SoMachine-NetworkNon isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-NetworkEthernet
Port Ethernet: 10BASE-T/100BASE-TX 1 port with 100 m copper cable
Communication service: Modbus TCP serverModbus TCP slave deviceDHCP clientModbus TCP clientEthernet/IP adapter
Local signalling: 1 LED (green) for PWR1 LED (green) for RUN1 LED (red) for module error (ERR)1 LED (green) for SD card access (SD)1 LED (red) for BAT1 LED per channel (green) for I/O state1 LED (green) for SLEthernet network activity (green) for ACTEthernet network link (yellow) for Link (Link Status)
Electrical connection: removable screw terminal block for inputs removable screw terminal block for outputs terminal block, 3 terminal(s) for connecting the 24 V DC power supply connector, 4 terminal(s) for analogue inputsMini B USB 2.0 connector for a programming terminal
Maximum cable distance between devices: Shielded cable: Unshielded cable: Unshielded cable: Unshielded cable:
Insulation: Between input and internal logic at 500 V ACNon-insulated between analogue input and internal logicNon-insulated between analogue inputsBetween supply and ground at 1500 V ACBetween sensor power supply and ground at 500 V ACBetween input and ground at 500 V ACBetween output and ground at 1500 V ACBetween supply and internal logic at 2300 V ACBetween sensor power supply and internal logic at 500 V ACBetween output and internal logic at 2300 V ACBetween Ethernet terminal and internal logic at 500 V ACBetween supply and sensor power supply at 2300 V AC
Marking: CE
Sensor power supply: 24 V DC at 250 mA supplied by the controller
Mounting support: Top hat type TH35-15 rail conforming to IEC 60715Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit
Height: 90 mm
Depth: 70 mm
Width: 110 mm
Net weight: 0.395 kg