Technical informations
Range: TeSys
Product name: TeSys VARIO
Device short name: VCCF
Product or component type: Emergency stop switch disconnector
Device composition: HandleShaft extensionSwitch
Mounting support: Handle: doorSwitch: symmetrical railSwitch: plate
Fixing mode: By 4 screws for handleBy clips for switchBy screws for switch
Performance level: High performance
Poles description: 3P
Contacts type and composition: 3 NO
[Ue] rated operational voltage: 690 V AC 50/60 Hz
Rated operational power in W: 30 kW at 230...240 V (AC-3)37 kW at 400...415 V (AC-3)37 kW at 690 V (AC-3)45 kW at 500 V (AC-3)45 kW at 690 V (AC-23A)55 kW at 500 V (AC-23A)30 kW at 230...240 V (AC-23A)45 kW at 400...415 V (AC-23A)
[Ie] rated operational current: 83 A AC-23 Ue: 400 V
[Ith] conventional free air thermal current: 175 A
[Ithe] conventional enclosed thermal current: 140 A
Making capacity: 1750 A at 400 V AC-21A1750 A at 400 V AC-22A1750 A at 400 V AC-23A
Breaking capacity: 1400 A at 400 V (AC-21A)1400 A at 400 V (AC-22A)1400 A at 400 V (AC-23A)
Rated conditional short-circuit current: 10 kA at 400 V - associated fuse 200 A aM10 kA at 400 V - associated fuse 200 A gG
[Icm] rated short-circuit making capacity: 2.8 kA at 400 V at Ipeak
[Icw] rated short-time withstand current: 2100 A at 400 V duration: 1 s
[Uimp] rated impulse withstand voltage: 8 kV
Suitability for isolation: Yes
Network type: ACDC
Intermittent duty class: 30
Control type: Rotary handle
Rotary handle mounting style: Extended
Handle colour: Red
Handle front plate colour: Yellow
Rotary handle padlocking: 1 to 3 padlocks 4...8 mm
Marking: 0 - 1
Mechanical durability: 30000 cycles
Electrical durability: 30000 cycles AC-2130000 cycles DC-1...5
Connections - terminals: Power circuit: screw clamp terminals95 mm² - solidPower circuit: screw clamp terminals70 mm² - flexible - with cable end
Tightening torque: Power circuit: 22.6 N.m - on screw clamp terminals
Base dimension: 90 x 90 mm
Height: 125 mm
Width: 90 mm
Product weight: 1.32 kg