SCHNEIDER
Télémécanique - limit switch XCR - metal stay put T rods lever square rod 6 mm - 2X(1NC+NO) - XCRF17
XCRF17
€214.80 Excl. Tax
€257.76 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 100€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | OsiSense XC |
---|---|
Series name: | Special format |
Product or component type: | Limit switch |
Product specific application: | For hoisting and mechanical handling applications |
Device short name: | XCR |
Sensor design: | - |
Body type: | Fixed |
Head type: | Rotary head |
Material: | Metal |
Fixing mode: | By the body |
Movement of operating head: | Rotary |
Type of operator: | Stay put crossed rods lever metal square rod 6 mm |
Type of approach: | Lateral approach, 2 directions |
Electrical connection: | Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² |
Number of poles: | 4 |
Contacts type and composition: | 2 x (1 NC + 1 NO) |
Contact operation: | Snap action |
Contact block per direction [control circuit]: | 1 per direction |
Positive opening: | With |
Body material: | Zinc alloy |
---|---|
Switch actuation: | By any moving part |
Cable entry: | 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9...12 mm conforming to NF C 68-300 |
Contacts insulation form: | Zb |
Number of steps: | 1 |
Positive opening minimum torque: | 0.7 N.m |
Minimum torque for tripping: | 0.6 N.m |
Minimum actuation speed: | 0.01 m/min |
Maximum actuation speed: | 1.5 m/s |
Maximum displacement angle: | -90 °90 ° |
Contact code designation: | A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix AQ300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
[Ui] rated insulation voltage: | 300 V conforming to UL 508500 V (pollution degree 3) conforming to IEC 60947-1500 V (pollution degree 3) conforming to VDE 0110300 V conforming to CSA C22.2 No 14 |
Maximum resistance across terminals: | 25 MOhm conforming to IEC 60255-7 category 3 |
[Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 606646 kV conforming to IEC 60947-1 |
Short-circuit protection: | 10 A cartridge fuse, type gG |
Electrical durability: | 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate |
Mechanical durability: | 10000000 cycles |
Width: | 85 mm |
Height: | 95 mm |
Depth: | 75 mm |
Product weight: | 1.135 kg |
Terminals description ISO n°1: | (13-14)NO(21-22)NC |
Compatibility code: | XCR |
In short
Reference XCRF17
Product Name Télémécanique - limit switch XCR - metal stay put T rods lever square rod 6 mm - 2X(1NC+NO) - XCRF17
Related Categories