Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
100 products at 10% off until 18 November! Find out more
SCHNEIDER

module XPSAXE - stop and switch monitoring - 24 V DC - XPSAXE5120P

XPSAXE5120P

Product not available. Here is the equivalent reference that we offer: XPSBAC14AP - Estop or guard ,Harmony XPS, connected to supply terminals 24 V AC/DC , no inputs, screw
Technical informations
Range of product: Preventa Safety automation
Product or component type: Preventa safety module
Safety module name: XPSAXE
Safety module application: For emergency stop and switch monitoring
Safety level: Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
Safety reliability data: DC > 99 % conforming to EN/ISO 13849-1MTTFd = 457 years conforming to EN/ISO 13849-1PFHd = 3E-8 1/h conforming to EN/IEC 62061
Connections - terminals: Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable endCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable endCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable endCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable endCaptive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel
Output type: Relay instantaneous opening, 3 NO circuit(s), volt-free
Number of additional circuits: 1 NC
[Us] rated supply voltage: 24 V DC - 15...10 %24 V AC
Synchronisation time between inputs:
Supply frequency: 50/60 Hz
Maximum power consumption in VA: 4 VA DC
[Uc] control circuit voltage: 24 V DC
Breaking capacity: 3600 VA inrush AC-15 B300 relay output360 VA holding AC-15 B300 relay output
Breaking capacity: 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
Output thermal current: 6 A for instantaneous and time delay outputs
Associated fuse rating: 6 A gG for instantaneous outputs
Minimum output current: 10 mA for relay output
Minimum output voltage: 17 V for relay output
Maximum response time on input open: 80 ms
[Ui] rated insulation voltage: 300 V (pollution degree 2) conforming to IEC 60947-5-1300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage: 4 kV overvoltage category III conforming to IEC 60947-5-14 kV overvoltage category III conforming to DIN VDE 0110 part 1
Local signalling: 2 LEDs
Mounting support: 35 mm symmetrical DIN rail
Product weight: 0.229 kg
In short
Reference XPSAXE5120P
Product Name module XPSAXE - stop and switch monitoring - 24 V DC - XPSAXE5120P
Related Categories