Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

Estop or guard ,Harmony XPS, connected to supply terminals 24 V AC/DC , no inputs, screw - XPSBAC14AP

XPSBAC14AP

€134.44 Excl. Tax
€161.33 Inc. Tax
available In stock more than 100 units – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range of product: Harmony Safety Automation
Product or component type: Safety module
Safety module name: XPSBAC
Safety module application: For emergency stop and protective guard applications
Function of module: Emergency stop button with 2 NC contactsGuard monitoring with 1 or 2 limit switches
Safety level: Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1Can reach SILCL 3 for normally open relay contact conforming to IEC 62061Can reach SIL 3 for normally open relay contact conforming to IEC 61508Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
Safety reliability data: MTTFd > 30 years conforming to ISO 13849-1 for normally open relay contactDcavg >= 99 % conforming to ISO 13849-1 for normally open relay contactPFHd = 0.95E-09 conforming to ISO 13849-1 for normally open relay contactHFT = 1 conforming to IEC 62061 for normally open relay contactPFHd = 0.95E-09 conforming to IEC 62061 for normally open relay contactSFF > 99% conforming to IEC 62061 for normally open relay contactHFT = 1 conforming to IEC 61508-1 for normally open relay contactPFHd = 0.95E-09 conforming to IEC 61508-1 for normally open relay contactSFF > 99% conforming to IEC 61508-1 for normally open relay contactType = B conforming to IEC 61508-1 for normally open relay contactMTTFd > 30 years conforming to ISO 13849-1 for normally closed relay contactDC > 60 % conforming to ISO 13849-1 for normally closed relay contactPFHd = 0.95E-09 conforming to ISO 13849-1 for normally closed relay contactHFT=0 conforming to IEC 62061 for normally closed relay contactPFHd = 0.95E-09 conforming to IEC 62061 for normally closed relay contactSFF > 60% conforming to IEC 62061 for normally closed relay contactHFT=0 conforming to IEC 61508-1 for normally closed relay contactPFHd = 0.95E-09 conforming to IEC 61508-1 for normally closed relay contactSFF > 60% conforming to IEC 61508-1 for normally closed relay contactType = B conforming to IEC 61508-1 for normally closed relay contact
Electrical circuit type: NC pair
Connections - terminals: Removable screw terminal block, 0.2...2.5 mm² solid or flexibleRemovable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductorRemovable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductorRemovable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezelRemovable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
[Us] rated supply voltage: 24 V AC - 15...10 %24 V DC - 20...20 %
Synchronisation time between inputs: Unlimited
Type of start: Automatic/manual/monitored
Power consumption in W: 1.5 W 24 V DC
Power consumption in VA: 3.5 VA 24 V AC 50/60 Hz
Input protection type: Internal, electronic
Auxiliary contact composition: 4 NO + 1 NC
Number of inputs: 0
Input compatibility: Normally closed circuit conforming to ISO 14119XC limit switch conforming to ISO 14119Mechanical contact conforming to ISO 14119Normally closed circuit conforming to ISO 13850
Terminal identifier: Power supply
[Ie] rated operational current: 5 A AC-1 for normally open relay contact3 A AC-15 for normally open relay contact5 A DC-1 for normally open relay contact3 A DC-13 for normally open relay contact3 A AC-1 for normally closed relay contact1 A AC-15 for normally closed relay contact3 A DC-1 for normally closed relay contact1 A DC-13 for normally closed relay contact
Number of outputs: 0
[Ith] conventional free air thermal current: 6 A
Associated fuse rating: 10 A gG for NO relay output circuit conforming to IEC 60947-1
Minimum output current: 10 mA for relay output
Minimum output voltage: 5 V for relay output
Response time: 150 ms at 24 V AC80 ms at 24 V DC
[Ui] rated insulation voltage: 300 V (pollution degree 2) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage: 4 kV overvoltage category II conforming to EN/IEC 60947-1
Local signalling: LED green with power marking for power ONLED red with error marking for errorLED yellow with state marking for statusLED yellow with start1 marking for start inputLED yellow with start2 marking for start input
Mounting support: 35 mm symmetrical DIN rail
Depth: 120 mm
Height: 100 mm
Width: 22.5 mm
Net weight: 0.200 kg
In short
Reference XPSBAC14AP
Product Name Estop or guard ,Harmony XPS, connected to supply terminals 24 V AC/DC , no inputs, screw - XPSBAC14AP
Related Categories