SCHNEIDER
module XPSVN - zero speed detection - 230 V DC for motor power supply <= 60 Hz - XPSVNE3742P
XPSVNE3742P
Obsolete product, here is the proposed substitution for the reference XPSVNE3742P : XPSUVN31AP
Technical informations
Range of product: | Preventa Safety automation |
---|---|
Product or component type: | Preventa safety module |
Safety module name: | XPSVNE |
Safety module application: | For zero speed detection |
Function of module: | Monitoring star-delta motor starter and guard switch type XCS EMonitoring 3-phase motor + variable speed driveMonitoring XPS AKMonitoring dc motorMonitoring 3-phase motor with variable number of poles and star-delta startingMonitoring 3-phase motorMonitoring 3-phase motor with star-delta starting |
Safety level: | Can reach PL d/category 3 conforming to EN/ISO 13849-1Can reach SILCL 2 conforming to EN/IEC 62061 |
Safety reliability data: | MTTFd = 124.1 years conforming to EN/ISO 13849-1DC > 99 % conforming to EN/ISO 13849-1PFHd = 9.26E-9 1/h conforming to EN/IEC 62061 |
Product certifications: | TÜVULCSA |
[Us] rated supply voltage: | 230 V AC - 15...10 % |
Output type: | Relay, 1 NO + 1 NC circuit(s), volt-free |
Number of additional circuits: | 2 solid state outputs |
Product destination: | For motor power supply |
---|---|
Power consumption in VA: | 7 VA |
Input voltage: | 500 Vrms |
Input detection threshold: | 0.01...0.1 V |
Breaking capacity: | 180 VA holding AC-15 C300 relay output1800 VA inrush AC-15 C300 relay output |
Breaking capacity: | 1.2 A at 24 V (DC-13) time constant: 50 ms for NC relay output circuit1.5 A at 24 V (DC-13) time constant: 50 ms for NO relay output circuit10 mA at 48 V for solid state output circuit20 mA at 24 V for solid state output circuit |
[Ith] conventional free air thermal current: | 2.5 A for relay output |
Associated fuse rating: | 4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
Standards: | EN/IEC 60947-5-1EN/IEC 60204-1 |
Minimum output current: | 10 mA for relay output |
Minimum output voltage: | 17 V for relay output |
[Ui] rated insulation voltage: | 300 V (pollution degree 2) conforming to IEC 60947-5-1300 V (pollution degree 2) conforming to DIN VDE 0110 parts 1 and 2 |
[Uimp] rated impulse withstand voltage: | 4 kV overvoltage category III conforming to IEC 60947-5-14 kV overvoltage category III conforming to DIN VDE 0110 parts 1 and 2 |
Local signalling: | 4 LEDs |
Connections - terminals: | Captive screw clamp terminals, removable terminal block flexible cable: 0.2...1.5 mm² without cable end, 2 wiresCaptive screw clamp terminals, removable terminal block flexible cable: 0.2...2.5 mm² without cable end, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable: 0.25...1 mm² with cable end, without bezel, 2 wiresCaptive screw clamp terminals, removable terminal block flexible cable: 0.25...2.5 mm² with cable end, with bezel, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable: 0.25...2.5 mm² with cable end, without bezel, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable: 0.5...1.5 mm² with cable end, with double bezel, 2 wiresCaptive screw clamp terminals, removable terminal block solid cable: 0.2...1 mm² without cable end, 2 wiresCaptive screw clamp terminals, removable terminal block solid cable: 0.2...2.5 mm² without cable end, 1 wire |
Mounting support: | 35 mm symmetrical DIN rail |
Depth: | 114 mm |
Height: | 99 mm |
Width: | 45 mm |
Product weight: | 0.6 kg |
In short
Reference XPSVNE3742P
Product Name module XPSVN - zero speed detection - 230 V DC for motor power supply <= 60 Hz - XPSVNE3742P
Range Automatisme de sécurité Preventa
Related Categories