Fast delivery - Satisfied or refunded for 14 days
9,3/10 out of 1126 reviews
SCHNEIDER

Télémécanique - Dual emergency stop rope pull switch, Telemecanique Emergency stop rope pull switches XY2C, e 2x(1NC+1NO), Pg13.5, boot. pb - XY2CEDA290

XY2CEDA290

€360.75 Excl. Tax
€432.90 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa fintecture alma applepay
Technical informations
Range of product: Telemecanique Emergency stop rope pull switches XY2C
Product or component type: Dual emergency stop rope pull switch
Device short name: XY2CED
Housing colour: Red RAL 3000
Overvoltage category: Class I conforming to EN/IEC 61140
Local signalling: Without pilot light
Number of cables: 2
Trigger cable maximum length: 2 x 100 m
Bellow material: Nitril
Body material: Zamak
Cover material: Stainless steel
Reset: By booted push-button
Contacts type and composition: 2 x (1 NC + 1 NO)
Contact operation: Slow-break
Trigger cable anchor point: RH and LH sides
Connections - terminals: Screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
Tightening torque: 0.8...1.2 N.m
Cable entry number: 3 plain hole for Pg 13.5 or ISO M20 cable gland
Safety level: Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Safety reliability data: B10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
Marking: CE
Mechanical durability: 60000 cycles
Distance between cable supports: 3...5 m
[Ie] rated operational current: 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current: 10 A
[Ui] rated insulation voltage: 500 V (pollution degree 3) conforming to EN/IEC 60947-1300 V conforming to UL 508300 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage: 6 kV conforming to EN/IEC 60947-1
Positive opening: With conforming to EN/IEC 60947-5-1
Maximum resistance across terminals: 25 MOhm conforming to EN/IEC 60255-7 category 3
Short-circuit protection: 10 A cartridge fuse type gG conforming to EN/IEC 60269
Terminals description ISO n°1: (13-14)NO(21-22)NC
Product weight: 1.9 kg
Compatibility code: XY2CED
In short
Reference XY2CEDA290
Product Name Télémécanique - Dual emergency stop rope pull switch, Telemecanique Emergency stop rope pull switches XY2C, e 2x(1NC+1NO), Pg13.5, boot. pb - XY2CEDA290
Related Categories