SCHNEIDER
iC60N - miniature circuit breaker - 1P - 32A - C curve - A9F04132
A9F04132
7,24 € HT
8,69 € TTC
HT
HT
TTC
TTC
Vous économisez
En cours d’approvisionnement – Délai moyen 4/6 semaines
- Support technique et interlocuteur unique dédié
- Livraison offerte dès 200€ d’achat (France Métropolitaine)
- Paiements 100% sécurisés
Informations techniques
Device application : | Distribution |
---|---|
Range : | Acti 9 |
Product name : | Acti 9 iC60 |
Product or component type : | Miniature circuit-breaker |
Device short name : | IC60N |
Poles description : | 1P |
Number of protected poles : | 1 |
[In] rated current : | 32 A |
Network type : | ACDC |
Trip unit technology : | Thermal-magnetic |
Curve code : | C |
Breaking capacity : | 10 kA Icu conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz20 kA Icu conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz6000 A Icn conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz10 kA Icu conforming to EN/IEC 60947-2 - 60...72 V DC15 kA Icu conforming to EN/IEC 60947-2 - 12...60 V DC36 kA Icu conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz |
Utilisation category : | Category A conforming to EN 60898-1Category A conforming to IEC 60898-1 |
Suitability for isolation : | Yes conforming to EN 60947-2Yes conforming to IEC 60947-2Yes conforming to EN 60898-1Yes conforming to IEC 60898-1 |
Standards : | EN 60898-1EN 60947-2IEC 60898-1IEC 60947-2 |
Network frequency : | 50/60 Hz |
---|---|
Magnetic tripping limit : | 8 x In +/- 20 % |
[Ics] rated service breaking capacity : | 10 kA 100 % x Icu conforming to EN 60947-2 - 72 V DC10 kA 100 % x Icu conforming to IEC 60947-2 - 72 V DC6000 A 100 % x Icu conforming to IEC 60898-1 - 230 V AC 50/60 Hz15 kA 100 % x Icu conforming to EN 60947-2 - 12...60 V DC15 kA 100 % x Icu conforming to IEC 60947-2 - 12...60 V DC6000 A 100 % x Icu conforming to EN 60898-1 - 230 V AC 50/60 Hz27 kA 75 % x Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz7.5 kA 75 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz27 kA 75 % x Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz7.5 kA 75 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz15 kA 75 % x Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz15 kA 75 % x Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz |
Limitation class : | 3 conforming to EN 60898-13 conforming to IEC 60898-1 |
[Ui] rated insulation voltage : | 500 V AC 50/60 Hz conforming to IEC 60947-2500 V AC 50/60 Hz conforming to EN 60947-2 |
[Uimp] rated impulse withstand voltage : | 6 kV conforming to EN 60947-26 kV conforming to IEC 60947-2 |
Contact position indicator : | Yes |
Control type : | Toggle |
Local signalling : | Trip indicator |
Mounting support : | DIN rail |
9 mm pitches : | 2 |
Height : | 91 mm |
Width : | 18 mm |
Depth : | 78.5 mm |
Product weight : | 0.125 kg |
Colour : | White |
Mechanical durability : | 20000 cycles |
Electrical durability : | 10000 cycles |
Connections - terminals : | Double terminal, top or bottom rigid wire(s) 1...35 mm² maxDouble terminal, top or bottom flexible wire(s) 1...25 mm² max |
Wire stripping length : | 14 mm top or bottom |
Tightening torque : | 3.5 N.m top or bottom |
Earth-leakage protection : | Without |
En bref
Référence A9F04132
Nom du produit iC60N - miniature circuit breaker - 1P - 32A - C curve - A9F04132
Gamme Acti 9
Fonction de l'appareil Distribution
Catégories associées